Name | Significance | computers | Cm name |
---|---|---|---|
TolmProcessor | real time and DAC interfacing | pc-calva2 | calvaTpr |
Pr | Photodiode Readout based on ADC signals, allow also some operations on the signals | pc-calva2 | CalvaPr |
GcLocking | Global control system, correct only the length of the cavities | pc-calva2 | Calva_Locking |
LcLocking | Local Control system, will correct angle and z based on red laser. | pc-calva2 | LC_Calva_Locking |
FreqStab | Laser frequency and power stabilization, control 1064 and 1319 nm lasers | pc-calva2 | Laser_CALVA_Locking |
TolmDac | Configuration and driving of the DAC board - 1 channel per coil and laser corrections. Also decide which z correction to send depending of the status of GcLoking and LcLocking | pc-calva2 | DAC |
TolmFb | Frame builder from the real time applications | pc-calva2 | calvaTfb |
RawToWrite | Send frames to process via TCP/IP | pc-calva2 | |
FdWRaw | GEt data from RawToWrite ans store on disk | pc-calva1 | |
FmRaw | List frames as ffl file on disk | pc-calva1 | |
FbsMoni | Get data from RawToWrite and send them to FbmToWrite | pc-calva1 | |
FbmMain | Get data from RawToWrite and send them to FbmToWrite | pc-calva1 | |
FromMain | Get data from RawToWrite and send them to FbmToWrite | pc-calva1 | |
MultiMeas | To use Agilent DataLogger for thermic measurement | ||
CtrlDelay | Change delay lines values | ||
Fbt50Raw | Get, subsample at 50 Hz and store datas in memory | pc-calva2 | |
Fbm50 | Retrieve datas in memory | pc-calva2 | |
Fbt50Write | Store datas | pc-calva1 | |
Fm50Hz | List frames as ffl file on disk | pc-calva1 | |
FbtMain | Create trend datas | pc-calva4 | |
FmTrend | Create trend datas | pc-calva4 | |
FbmToDy | non active | pc-calva1 | |
Fbm50Users | Allow access to 50 Hz online data | pc-calva1 | |
FbmTestDy | Allow access to full sampling online datas (10, 20 or 160 kHz) | pc-calva1 |
Name | Significance | computers | Cm name |
---|---|---|---|
TolmProcessor | real time and DAC interfacing | pc-calva2 | calvaTpr |
Pr | Photodiode Readout based on ADC signals, allow also some operations on the signals | pc-calva2 | CalvaPr |
GcLocking | Global control system, correct only the length of the cavities | pc-calva2 | Calva_Locking |
LcLocking | Local Control system, will correct angle and z based on red laser. | pc-calva2 | LC_Calva_Locking |
FreqStab | Laser frequency and power stabilization, control 1064 and 1319 nm lasers | pc-calva2 | Laser_CALVA_Locking |
TolmDac | Configuration and driving of the DAC board - 1 channel per coil and laser corrections. Also decide which z correction to send depending of the status of GcLoking and LcLocking | pc-calva2 | DAC |
TolmFb | Frame builder from the real time applications | pc-calva2 | calvaTfb |
RawToWrite | Send frames to process via TCP/IP | pc-calva2 | |
FdWRaw | GEt data from RawToWrite ans store on disk | pc-calva1 | |
FmRaw | List frames as ffl file on disk | pc-calva1 | |
FbsMoni | Get data from RawToWrite and send them to FbmToWrite | pc-calva1 | |
FbmMain | Get data from RawToWrite and send them to FbmToWrite | pc-calva1 | |
FromMain | Get data from RawToWrite and send them to FbmToWrite | pc-calva1 | |
MultiMeas | To use Agilent DataLogger for thermic measurement | ||
CtrlDelay | Change delay lines values | ||
Fbt50Raw | Get, subsample at 50 Hz and store datas in memory | pc-calva2 | |
Fbm50 | Retrieve datas in memory | pc-calva2 | |
Fbt50Write | Store datas | pc-calva1 | |
Fm50Hz | List frames as ffl file on disk | pc-calva1 | |
FbtMain | Create trend datas | pc-calva4 | |
FmTrend | Create trend datas | pc-calva4 | |
FbmToDy | non active | pc-calva1 | |
Fbm50Users | Allow access to 50 Hz online data | pc-calva1 | |
FbmTestDy | Allow access to full sampling online datas (10, 20 or 160 kHz) | pc-calva1 |